EasyManua.ls Logo

Zodiac eXO iQ 10 - User Manual

Zodiac eXO iQ 10
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
H0632500.B- 2019/11 - ES11--
More documents on:
www.zodiac.com
Instruc ons for installa on and use - English
Salt water chlorinator, pH/Redox regula on
Transla on of the original instruc ons in french
EN
pH Link / Dual Link
eXO®/ eXO® iQ (LS)
GenSalt OT

Questions and Answers

  • L
    Laura GrahamAug 12, 2025
    What to do if Zodiac eXO iQ 10 Water Filtration Systems show 'NO FLOW CHECK PUMP'?
    • C
      crawfordmichaelAug 13, 2025
      If your Zodiac Water Filtration System displays 'NO FLOW CHECK PUMP', it could be due to a few reasons. The filter pump may have failed, or the filter and/or skimmer(s) might be dirty, or the by-pass valve(s) are closed, or there is a disconnection or failure of the flow switch. Start by checking the pump, filter, skimmer(s), and by-pass valve(s), cleaning them if needed. Also, check the wire connections to the flow switch. If that doesn't resolve the issue, ensure the flow switch is working correctly and replace it if necessary.
  • E
    Emily YoungAug 16, 2025
    Why does my Zodiac eXO iQ 10 Water Filtration Systems show a 'CONDUCTIVITY' error?
    • J
      jaimejimenezAug 16, 2025
      A 'CONDUCTIVITY' error on your Zodiac Water Filtration System can stem from several causes. For models equipped with a temperature sensor, low water conductivity (low salt levels) could be the culprit. If there's no temperature sensor, the error might indicate low water temperature or low salt. Additionally, the cell could be worn, scaled up, or broken. Start by checking the water temperature. Measure the salt concentration in the pool water using a salt tester or a test strip, then add salt to the pool to keep the level at 4 g/L or 2 g/L depending on the model. Check the condition of the cell plates.
  • W
    wbentleyAug 20, 2025
    What causes a 'PROD. ERROR' in Zodiac eXO iQ 10 Water Filtration Systems?
    • M
      michelle30Aug 20, 2025
      A 'PROD. ERROR' on your Zodiac Water Filtration System can be caused by a poor connection of the power supply cord from the cell to the cell or inside the appliance, worn, scaled up, or broken cell plates, or an internal electronic problem in the control box following an external electric incident. First, switch off the appliance and the power supply to the control box, then check the connections for all cables (mains power supply, cell, etc.). If the problem persists, replace the cell. If the issue is still not resolved, check the power supply board by contacting your retailer.
  • P
    palmertimothyAug 25, 2025
    How to fix Zodiac Water Filtration Systems overheating?
    • M
      mcphersonyolandaAug 25, 2025
      If your Zodiac Water Filtration System is overheating, it's likely because the temperature inside the control box is too high. Chlorination slows above 85°C and stops above 90°C to protect the electric circuits. If the box is installed outdoors, protect it from direct sunlight. Chlorination resumes automatically once the temperature has fallen back down. If the issue persists, it may indicate a problem with the appliance.
  • J
    James CarterAug 28, 2025
    What to do if Zodiac eXO iQ 10 displays 'pH LOW'?
    • K
      Kenneth SmithAug 28, 2025
      If your Zodiac Water Filtration System displays 'pH LOW', it indicates that the pH is less than 5, or there is a faulty connection or calibration error, pH sensor failure or dirty, or low alkalinity, reduced pH. Check the pH sensor wiring on the control box and on the sensor holder. Check the operation of the sensor using a sensor tester (contact your retailer). Check and adjust the alkalinity.
  • D
    Danielle GreenAug 31, 2025
    Why does Zodiac eXO iQ 10 stop due to 'LOW WATER TEMP.'?
    • R
      Roger SmithAug 31, 2025
      Your Zodiac Water Filtration System stops due to 'LOW WATER TEMP.' because the water temperature measured by the appliance's temperature sensor is less than or equal to 10°C; production stops in order to protect the cell. Chlorination will automatically resume at the Low mode chlorination rate between 10 and 15°C and at the normal chlorination rate when the temperature exceeds 15°C.
  • L
    Laura StevensSep 4, 2025
    Why is there no chlorine production visible on my Zodiac eXO iQ 10 Water Filtration Systems?
    • M
      mmooreSep 4, 2025
      If you observe no visible chlorine production on the cell plates of your Zodiac Water Filtration System, it could be because chlorination is in the reversal period, or chlorination is set to less than 100% and is stopped. Wait and see. Chlorination should resume within the next 10 minutes.
  • J
    johnsonbryanSep 8, 2025
    What causes data loss in Zodiac eXO iQ 10?
    • K
      Kevin MyersSep 8, 2025
      Data loss (time, etc.) in your Zodiac Water Filtration System can be attributed to a dead battery or a power cut. If it's due to a dead battery, contact your retailer to replace the 3V CR1220 battery. If due to a power cut, wait for the power to be restored. The appliance should automatically recover the information saved before the power cut.

Summary

Important Safety Warnings

General Safety Precautions

Covers risks of damage, injury, and proper use by qualified personnel.

Electrical Safety Precautions

Power Supply and Protection Requirements

Details requirements for power supply protection and proper connections.

Troubleshooting Guide

Product Specifications

Chlorinator Technical Data

Provides detailed technical specifications for the salt water chlorinator models.

Installing the Salt Water Chlorinator

Electrolytic Cell Installation

Instructions for installing the main electrolytic cell, including dimensions.

GenSalt OT Cell Installation Details

Specific instructions and diagrams for installing the GenSalt OT cell.

Temperature and Flow Sensor Installation

Guides for installing the temperature sensor and flow switch.

Control Box Installation Procedures

Steps and considerations for installing the main control box.

Electrical Connections

Accessing Electrical Terminal Blocks

Steps to open the control box and access the terminal blocks for wiring.

Terminal Block Function Identification

Identifies the function and connection type for each terminal block.

Step-by-Step Electrical Wiring

Detailed instructions and diagrams for performing the electrical connections.

Installing pH Link or Dual Link Module

Module Installation Procedure

Step-by-step guide for installing the pH Link or Dual Link module.

Installing the POD Kit

Pipe Preparation for POD Kit Installation

Instructions on how to prepare the pool pipe for fitting the POD kit.

Mounting the POD Kit on the Pipe

Detailed steps for physically mounting the POD kit onto the prepared pipe.

Flow Switch Installation on POD Kit

Specific instructions for installing the flow switch within the POD kit assembly.

Installing pH and ORP Sensors in POD Kit

Guide for correctly installing the pH and ORP sensors into the POD kit.

Installing pH Minus Lines

pH Minus Injection Line Setup

Instructions for connecting the pH minus injection hose to the peristaltic pump.

pH Minus Suction Line Setup

Instructions for connecting the pH minus suction hose to the chemical container.

Preparing the Pool for Operation

Water Balancing and Analysis

Guidelines for analyzing and adjusting water parameters like hardness, alkalinity, and pH.

Appliance Operation and User Interface

Sensor Calibration and Configuration

Routine Operational Modes

Remote Control with iAquaLink App

Appliance Care and Maintenance

Troubleshooting Appliance Issues

Zodiac eXO iQ 10 Specifications

General IconGeneral
BrandZodiac
ModeleXO iQ 10
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals