Instruc ons for installa on and use - English
Salt water chlorinator, pH/Redox regula on
Transla on of the original instruc ons in french
EN
pH Link / Dual Link
eXO®/ eXO® iQ (LS)
GenSalt OT

Questions and Answers

  • J
    Jodi PayneSep 9, 2025
    What causes 'ORP PROD. STOP' in Zodiac Water Filtration Systems and how to resolve it?
    • D
      Dennis SmithSep 9, 2025
      The 'ORP PROD. STOP' error in your Zodiac Water Filtration System indicates that the ORP setpoint hasn't been reached after prolonged chlorination. You should check the pool's chlorine level using a photometer or test strip, and inspect the ORP sensor wiring on both the control box and sensor holder. High cyanuric acid levels can also interfere with chlorine's effectiveness and ORP readings, so empty the pool using the bottom drain to reduce cyanuric acid concentration and perform shock chlorination with calcium hypochlorite to reduce chloramines. Also, check the condition of the cells and consider replacing the ORP sensor.
  • B
    brian60Aug 23, 2025
    What to do if my Zodiac Water Filtration Systems shows 'NO FLOW CHECK PUMP'?
    • J
      Jimmy SmithAug 23, 2025
      If your Zodiac Water Filtration System displays 'NO FLOW CHECK PUMP', it indicates a problem with water circulation. This can be due to a filter pump failure, dirty filter or skimmer(s), or closed by-pass valve(s). Inspect the pump, filter, skimmer(s), and by-pass valve(s), cleaning them as needed. Also, check the flow switch wire connections and ensure the flow switch is working correctly; replace it if necessary.
  • K
    Kendra GonzalezAug 25, 2025
    Why does my Zodiac eXO iQ 18 show a 'CONDUCTIVITY' error?
    • G
      Gerald CollinsAug 26, 2025
      A 'CONDUCTIVITY' error on your Zodiac Water Filtration System can stem from several causes. For models equipped with a temperature sensor, low water conductivity (low salt levels) could be the culprit. If there's no temperature sensor, the error might indicate low water temperature or low salt. Additionally, the cell could be worn, scaled up, or broken. Start by checking the water temperature. Measure the salt concentration in the pool water using a salt tester or a test strip, then add salt to the pool to keep the level at 4 g/L or 2 g/L depending on the model. Check the condition of the cell plates.
  • R
    Ricky RaymondAug 27, 2025
    What causes a 'PROD. ERROR' in Zodiac Water Filtration Systems?
    • B
      Barbara WoodAug 27, 2025
      A 'PROD. ERROR' on your Zodiac Water Filtration System can be caused by a poor connection of the power supply cord from the cell to the cell or inside the appliance, worn, scaled up, or broken cell plates, or an internal electronic problem in the control box following an external electric incident. First, switch off the appliance and the power supply to the control box, then check the connections for all cables (mains power supply, cell, etc.). If the problem persists, replace the cell. If the issue is still not resolved, check the power supply board by contacting your retailer.
  • D
    Darius OconnorAug 27, 2025
    How to fix Zodiac eXO iQ 18 Water Filtration Systems overheating?
    • S
      Sherry ThomasAug 27, 2025
      If your Zodiac Water Filtration System is overheating, it's likely because the temperature inside the control box is too high. Chlorination slows above 85°C and stops above 90°C to protect the electric circuits. If the box is installed outdoors, protect it from direct sunlight. Chlorination resumes automatically once the temperature has fallen back down. If the issue persists, it may indicate a problem with the appliance.
  • M
    morganjoshuaAug 29, 2025
    What to do if Zodiac eXO iQ 18 Water Filtration Systems displays 'pH LOW'?
    • K
      Kent SchroederAug 29, 2025
      If your Zodiac Water Filtration System displays 'pH LOW', it indicates that the pH is less than 5, or there is a faulty connection or calibration error, pH sensor failure or dirty, or low alkalinity, reduced pH. Check the pH sensor wiring on the control box and on the sensor holder. Check the operation of the sensor using a sensor tester (contact your retailer). Check and adjust the alkalinity.
  • M
    Matthew CarterSep 18, 2025
    What causes a 'pH LOW' error on my Zodiac Water Filtration Systems?
    • G
      gfrostSep 18, 2025
      A 'pH LOW' error on your Zodiac Water Filtration System indicates that the pH is less than 5. Check the pH sensor wiring on the control box and the sensor holder. Also, a faulty connection, calibration error, pH sensor failure, or a dirty sensor could be the cause, so check the sensor's operation. Low alkalinity can also reduce pH, so check and adjust the alkalinity.
  • S
    salasannaSep 22, 2025
    What causes data loss (time, etc.) in my Zodiac Water Filtration Systems?
    • Z
      zolsonSep 22, 2025
      Data loss (like time) in your Zodiac Water Filtration System is typically due to a dead battery or a power cut. If it's a dead battery, contact your retailer to replace the 3V CR1220 battery. If it's due to a power cut, wait for the power to be restored; the appliance should automatically recover the information saved before the power cut.
  • D
    daguilarSep 7, 2025
    What should I do if pH dosing STOP on my Zodiac Water Filtration Systems?
    • J
      Jeffrey RamseySep 8, 2025
      If the pH dosing stops on your Zodiac Water Filtration System, it means that the pH value measured remains higher than the pH setpoint. To solve this problem you should check or replace the container, check and adjust the alkalinity (TA) of the pool water, and check/clean or replace the pH sensor.
  • J
    Juan MooreSep 4, 2025
    Why does my Zodiac Water Filtration Systems show a conductivity error?
    • T
      tkimSep 4, 2025
      A conductivity error in your Zodiac Water Filtration System could be due to several reasons. If your model has a temperature sensor, low water conductivity (low salt) might be the cause, so check the water temperature. It can also be caused by low salt levels due to water loss or dilution from filter backwash, water renewal, rain, or leaks. Measure the salt concentration using a salt tester or test strip, and add salt to maintain the level at 4 g/L or 2 g/L, depending on your model. Also, check the condition of the cell plates.

Summary

eXO;eXO iQ (LS) GenSalt OT Installation and Use Manual

General Warnings

Safety instructions to prevent damage or injury.

Electrical Appliance Warnings

Safety precautions for electrical components and usage.

Installing the Salt Water Chlorinator

Installing the Cell

Procedure for installing the electrolytic cell.

Electrical Connections

Steps and guidelines for electrical connections.

Preparing the Pool

Balancing the Water

Guidelines for adjusting water parameters (pH, TA, TH).

Adding Salt

Procedure for adding salt to the pool water.

Using the Appliance

Calibrating Sensors

Guide to calibrating pH and ORP sensors.

Troubleshooting Common Issues

Appliance Behaviour Messages

Explains appliance messages and potential causes.