21
❹ Troubleshoong
If a problem occurs, before you contact your retailer, please carry out these few simple checks
using the following tables.
If the problem is not resolved, contact your retailer.
: Acons to be performed by a qualied technician only.
4.1 I Appliance behaviour
Part of the pool is not correctly
cleaned
Repeat the immersion steps (see § « 2.1 I Immersing the cleaner in the
pool »), varying the immersion locaon unl you nd the right place in the
pool.
The appliance does not stay rmly
on the pool boom
There is sll air in the appliance's casing. Repeat the immersion operaons
(see § « 2.1 I Immersing the cleaner in the pool »).
The lter is full or clogged: clean it with fresh water. If the lter is blocked,
clean it with an acid soluon (spirit vinegar, for example). Replace the lter
if necessary.
The propeller is damaged:
The appliance does not or no
longer climbs the pool sides as it
originally did.
(Its electronic programme means
that the appliance does not
systemacally climb the walls).
The lter is full or clogged: clean it with fresh water. If the lter is blocked,
clean it with an acid soluon (spirit vinegar, for example). Replace the lter
if necessary.
The tyres are worn: replace them.
Even though the water seems clear, microscopic algae are present in your
pool. They are not visible to the naked eye, and they make the walls slippery
and prevent the appliance from climbing. Carry out shock chlorinaon and
slightly reduce the pH. Do not leave the appliance in the water during shock
treatment.
The brushes are worn: check the wear indicators § « 3.4 I Replacing the
brushes », then turn the brushes to check the rotaons. Replace the brushes
where necessary.
The appliance does not move on
start-up.
Check that the control box's power socket is receiving a power supply.
Check that a cleaning cycle has been launched and that the lights are on.
The cable gets tangled
Do not unroll the enre length of the cable into the pool.
Place the required length of cable in the pool and spread the rest along the
side of the pool.
The cleaner's discharge nozzles or
boom plug holes become blocked
Stop the lter pump and begin a new cleaning cycle.
Place the control box halfway along the length of the pool, in accordance
with the safety condions, see § « 2.3 I Electricity supply connecon ». If
cleaning is not opmal, vary the locaon of the control box and the place at
which the cleaner enters the pool.
The cleaner climbs the walls slowly
and stops under the water line
The cleaner climbs the walls quickly
and goes past the water line,
aspirang air
The cleaner may behave dierently depending on the lining of the pool. A
parameter may require changing. To do this, contact your retailer
The control box does not respond
to any buon presses.
Unplug the power cord from the mains socket, wait 10 seconds and plug it
back in again.

Other manuals for Zodiac Vortex RV 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zodiac Vortex RV 5500 and is the answer not in the manual?

Zodiac Vortex RV 5500 Specifications

General IconGeneral
BrandZodiac
ModelVortex RV 5500
CategorySwimming Pool Vacuum
LanguageEnglish

Related product manuals