Chapter6
InstallationCheck
TableofContents
OverallInspection......................................................................................................6-1
Power-ON/OFFInspection.........................................................................................6-2
6.1OverallInspection
Overallinspectionincludesthefollowing:
lCabinetInspection
lCablingInspection
lShelfPowerSupplyInspection
lCardPowerSupplyInspection
CabinetInspection
Cabinetinspectionincludesthefollowing:
lTheverticaldeviationofthecabinetsshouldnotexceed3mm.
lMakesurethatthefront,back,andsidedoorshavebeenassembled.
lMakesurethatallthescrewshavebeentightened.
lMakesurethatnopartsofthecabinetfallofforaredamaged.Connectingcables
shouldbeintact.
lPlacethecabinetcloselytothenextoneatthesamelevelwhentheyarearranged
sidebyside.
lPlaceallthecabinetssteadilyandneatlywithconsistentgapbetweenrows,both
ends,andeachpoint.
lKeepthecabinetcleanandfreeofdust.
CablingInspection
Cablinginspectionincludescablelayoutinspection,andpowercableandgroundingcable
inspection.
lCablelayoutinspectionincludesthefollowing:
àTheturningsofcablesmustbeevenandsmooth.Keepcurvesverticalor
horizontalinastraightline.
àBindtailbersinsidethecabinetneatlyandgently.Protecttailbersbetween
cabinetswithsleeves.
àInstallationpositionsofcablingchutesandtroughsmustmeetrequirementsof
theconstructiondrawings.Deviationfromlefttorightcannotexceed50mm.
6-1
SJ-20110909101511-005|2011-12-31(R1.1)ZTEProprietaryandCondential