Chapter7RPS180BackupPower
LPDB
LPDBismainlyusedtooutput+12VDCpowerconvertedbyCAPU
orCDPUintothreeoutputsthroughltering,whichcanbeusedby
threelower-powerswitches.
1.Supportingfanmonitoringfunction
2.Supportinginputvoltagemonitoringfunction
3.TheLEDindicatorsonfrontpanelofdriveindicatesrespectively
thestatusofthreefansandinputvoltage.
InstallationandDebugging
EquipmentInstallation
ZXR10RPS180canbeplacedondesksorxedin19-inchstandard
cabinets.
Where,the19-inchstandardcabinetcanbeprovidedbytheuser .
IfZTE'scabinetistobeused,youneedrefertothe19-InchStan-
dardCabinetInstallationManualforcabinetinstallation.
DesktopInstallation
Installfourplasticbottomblocks(plasticbottomblocksarestrews
areprovidedtogetherwithdevice)onthebottomplateofswitch
toformanairpassage,forwhichheatgeneratedbypowermodule
canbedissipatedefciently.
CabinetInstallation
ToinstalltheZXR10RPS180intothe19-inchcabinet,itisneces-
sarytoinstallangestoeachsideoftheswitchshell(angeand
screwsarepartoftheaccessories).
CableInstallation
ZXR10RPS180cableconsistsofthepowercable,consolecable.
PowerCableInstallation
ThepowercableconsistsofACandDCpowercablesbasedonthe
powermodules:
CondentialandProprietaryInformationofZTECORPORATION39