ZXR105900/5200SeriesHardwareManual
TABLE17FIBERTYPES
ModeSwitchConnectorEndConnectorType
FC/PC
SC/PC
SingleMode
SC-PC(square
adapter)
ST/PC
FC/PC
SC/PC Multi-mode
SC-PC(square
adapter)
ST/P
Asforberoutofthecabinet,makesuretoprotecttheber
againstanydamageswithplasticcorrugatedsleeve.Theber
withintheprotectsleevemustnotbewoundupandthecorners
mustberadian.Thelabelsattwoendsofthebermustbeclear .
Themeaningofthelabelmustcorrectlyreectcorrespondingse-
rialnumbersandrelationshipbetweencabinetsandbetweenrows.
Power-onProcedure
Checktheequipmentroomenvironmentandhardwareinstallation
beforepoweringontheZXR105900/5200.
1.Checkwhethertheequipmentroomtemperature,humidity
andvoltagemeettheinstallationrequirements,asshownin
Table18.
TABLE18TEMPERATUREANDHUMIDITY
Temperature(℃)RH(%)
Item
Long-Term
Working
Condition
(Note1)
Short-Term
Working
Condition
(Note2)
Long-Term
Working
Condition
Long-Term
Working
Condition
Short-Term
Working
Condition
Scope15℃~30℃-5℃~45℃30%~70%20%~90%
1.UnderthenormalworkingenvironmentoftheZXR105900/5200,
themeasurementvaluesoftemperatureandhumidityrefertothose
measuredat2mabovetheoorand0.4minfrontofthedevice(the
measurementisdonewithnoprotectiveboardinthefrontoratthe
backofthecabinet).
2.Theshort-termworkingconditionmeansacontinuousrunningperiod
ofnotmorethan48hours,andaccumulatedrunningperiodsayear
ofnomorethan15days.
2.Checkwhetherthepowercablesandthecablesareconnected
correctlyandreliablyornot.
3.Checkotherhardware.
4.PowerontheZXR105900/5200inthefollowingsteps:
32CondentialandProprietaryInformationofZTECORPORATION