temperatur
e
TemperatureEventOn 1.3.6.1.4.1.890.1.5.8.52.3
1.2.1
1.3.6.1.4.1.890.1.5.8.39.3
1.2.1
1.3.6.1.4.1.890.1.5.8.46.3
1.2.1
This trap is sent when the
temperature goes above or
below the normal operating
range.
TemperatureEventClear 1.3.6.1.4.1.890.1.5.8.52.3
1.2.2
1.3.6.1.4.1.890.1.5.8.39.3
1.2.2
1.3.6.1.4.1.890.1.5.8.46.3
1.2.2
This trap is sent when the
temperature returns to the
normal operating range.
voltage VoltageEventOn 1.3.6.1.4.1.890.1.5.8.52.3
1.2.1
1.3.6.1.4.1.890.1.5.8.39.3
1.2.1
1.3.6.1.4.1.890.1.5.8.46.3
1.2.1
This trap is sent when the
voltage goes above or below the
normal operating range.
VoltageEventClear 1.3.6.1.4.1.890.1.5.8.52.3
1.2.2
1.3.6.1.4.1.890.1.5.8.39.3
1.2.2
1.3.6.1.4.1.890.1.5.8.46.3
1.2.2
This trap is sent when the
voltage returns to the normal
operating range.
reset UncontrolledResetEventOn 1.3.6.1.4.1.890.1.5.8.52.3
1.2.1
1.3.6.1.4.1.890.1.5.8.39.3
1.2.1
1.3.6.1.4.1.890.1.5.8.46.3
1.2.1
This trap is sent when the
Switch automatically resets.
ControlledResetEventOn 1.3.6.1.4.1.890.1.5.8.52.3
1.2.1
1.3.6.1.4.1.890.1.5.8.39.3
1.2.1
1.3.6.1.4.1.890.1.5.8.46.3
1.2.1
This trap is sent when the
Switch resets by an
administrator through a
management interface.
RebootEvent 1.3.6.1.4.1.890.1.5.1.1.2 This trap is sent when the
Switch reboots by an
administrator through a
management interface.
Table 146 SNMP System Traps (continued)