2 Go to Configuration > System > USB Storage, select Activate USB storage service and click
Apply to allow the ZyWALL to save diagnostic data to the connected USB device.
3 Go to Configuration > Log & Report > Log Setting, select the USB Storage entry and click
Edit.
4 In the Edit Log on USB Storage Setting screen, select Duplicate logs to USB storage.
Select the green check marks to log regular information and alerts from the corresponding
categories. You can also simply click Selection and then enable normal logs to select the green
check marks for all categories as shown in this example. Click OK.