2 EASY
Input the master code
(Default: # #
Beep+, Beep Beep+, Beep
Beep+
Beep+
10.Interference resistant
grade setting
Input the setting code. Input the setting code.
9. Call tone setting
08+#
0/1
1+#
09+#
Inputting of code (ex.: 3)
range:0~5
3+#
Inputting of code (ex.: 1)
range:0(enable)/1:(disable)
(Default 2)
(Default enable)
-
The larger you set the
interference resistant grade,
the stronger it will be,but the
sensitivity of the keypad will
be more lower.
- The interference resistant
grade setting also will activate
the keypad checking
-
If the item is set to 0,the unit will
respond a call tone when pressing
the “CALL” button.
- If set to 1, the unit will have no
respons when pressing the
“CALL” button
Beep+, Beep
Beep+
11.SPK volume adjust
setting
Input the setting code. Input the setting code.
11+#
Inputting of code (ex.: 5)
range:0~9
5+#
(Default:4)
- Unlock via password is still
available even when the door
station is talking
state
.
- When door station is talking,
you can enter the Master code
(the LED turns white upon that)
to activate the volume adjusting
function:
Speaker adjustment: 3 (up),
6 (down)
Beep+, Beep
Beep+
12.Night light level
setting
13+#
Inputting of code (ex.: 3)
range:0~5
3+#
(Default 4)
- Night Light Level:0~5. -
The higher the number, the
brighter the lights
Beep+, Beep
-
When the “ cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
-
When there isn’t any operation in 10s, the buzzer beeps, and the system exits the setting mode.
Beep, Beep+
*
-
When setting failure, the buzzer beeps.