Rack-mounting the Switch 23
Figure 5 Fitting a Bracket for Rack-Mounting
3 Insert the two screws and tighten with a suitable screwdriver.
You must use the screws supplied with the mounting brackets. Damage
caused to the unit by using incorrect screws invalidates your warranty.
4 Repeat step 2 and step 3 for the other side of the switch.
5 Insert the switch into the 19-inch rack and secure with suitable screws
(not provided). Ensure that ventilation holes are not obstructed.
6 Connect network cabling.
7 Place a unit information label on the unit in an easily accessible position.
The unit information label shows the following:
3Com switch product name
3Com switch 3C number
The switch’s unique MAC address (Ethernet address)
The switch’s serial number
You may need this information if you contact 3Com Technical Support.