Error 1905 Explanation: This error is caused by a layer that is too large for
the printer’s buffer. The printer is unable to process the layer and
reports the error. This is most common with GIS, architecture, and
scanned files, which are usually very large.
Solution: Try rotating the part on the X-Z-axis to increase the
layer count and reduce the size of each layer. The risk in doing this
is 3DPrint is unable to check for layer size before it begins the
build. We recommend reducing the detail on the file and trying the
print again.