11. Set-Up and Adjustments (continued)
Note:
Loosen
but do not
Remove
Column
Screws
Figure 11-7
A
B
305mm
Min.
11.5 Special Set-Up Procedure for Outer Column Re-Positioning (continued on next page)
Moving the outer columns will increase/decrease the maximum box height capacity of the
8000a-8000a3 case sealer.
1. Place solid blocks approximately 12” [305mm] high at front and rear of upper taping
head assembly as shown in Figure 11-7A.
2. Crank the upper taping head assembly down until it touches these blocks.
3. Loosen (but do not remove) the eight (8) screws and washers that fasten each column to
the frame (Figure 11-7B).
Note: You will also need to loosen the two (2) set screws in the nut plate bracket (located
above bottom two column screws).
4. Turn height adjustment crank clockwise to raise outer columns until they reach the stop.
Note: Instructions are indicated for the Standard Column Position (Also see speci cations).
If Alternate Column positions are needed, loosen and re-position the column stop.
5. Tighten the eight (8) screws and washers in each column.
Also tighten two Set Screws (if applicable)(continued on next page)
Figure 11-5
Figure 11-6
Figure 11-4
B
A