3.4 CABLE LIFELINES: Cable Lifelines come in custom lengths of 7 x 7 or 1 x 19 - 8 mm Stainless Steel Cable. 1 x 19 cable
is recommended for Overhead HLL systems where stiffer cable with less ex is needed.
8 mm 7 x 7 Stainless Steel Cable
8 mm 1 x 19 Stainless Steel Cable
7240211
7240212
7234012 Hex Joiner For swaging together sections of lengths of 8 mm Cable.
7241432 End Stopper Prevents travelers from colliding with Lifeline end
terminations.
1. Starting at the entrance point
to the system, thread the Cable
Lifeline through all Intermediate
Brackets and Corner Brackets.
2. Where additional lengths of cable
are needed, swage cable ends
together with a Hex Joiner. See
Swaging.
3. At the entrance point, swage the
required End Connector onto the
cable end. See Swaging.
4. Secure the Lifeline to the End
Anchor Bracket with the End
Connector and Energy Absorber
(if required). See End Connectors
and Energy Absorbers.
5. At the far end of the HLL, connect
the speci ed Energy Absorber and
End Connector to the End Anchor
Bracket. See End Connectors and
Energy Absorbers.
6. On Overhead HLL systems with
the Overhead Traveler, install
the Overhead Travelers on the
detached end of the Lifeline. See
Travelers.
7. Insert the free end of the Lifeline
through the Pass Through Hex
Swage Stud End Connector,
tension the Lifeline cable (see
Tensioning), and then swage the
cable in the End Connector (see
Swaging).
8. Where speci ed, install End
Stoppers on the Lifeline cable.