3.6 END CONNECTORS AND ENERGY ABSORBERS: Use End Connectors to terminate each end of the Cable Lifeline. A
Hex Swage Toggle is used where the Lifeline can be anchored directly to the End Anchor Bracket without tensioning and
an Energy Absorber. If an Ensd Stopper is needed, a Hex Swage Toggle with Shoulder can be used. A Pass Through Hex
Swage Stud is used where the Lifeline requires tensioning and an Energy Absorber.
End
Connectors Hex Swage Toggle Pass Through Hex Swage Stud
Hex Swage Toggle with Shoulder
7234011
7241430
7234246
Energy
Absorbers
Energy Absorber Dampener/Tension Indicator
System
Tension
kN (lbf)
Peak Arrest
Force
kN (lbf)
7241422
0.8 (180) 11 (2,500)
7241424
0.8 (180)
19 (4,270)
7241425
5 (1,125) 19 (4,270)
7241426
0.8 (180)
19 (4,270)
7241427
5 (1,125) 19 (4,270)
7241428
5 (1,125)
7241429
0.8 (180)
1. Fully insert the end of the Cable
Lifeline in the Swage Terminal on
the Hex Swage Toggle.
2. Swage the cable in the Hex
Swage Toggle with a Hex Swager.
See Swaging.
3. Remove the Toggle Pin from
the Hex Swage Toggle and then
secure the Hex Swage Toggle to
the End Anchor Bracket with the
Clevis Pin, Castle Nut, and Split
Pin.