EasyManua.ls Logo

3M Drive-Thru G5B1 - 7 Appendix: Induction Loop and Vehicle Detector Board Specifications; Internal Vehicle Detector Board Specifications; Saw - in Loop Specifications; Prefab Loop Specifications

3M Drive-Thru G5B1
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Instructions G5 - Revision C, September 2019
59
3M™ Drive-Thru System Model G5
Installation Instructions G5
Revision C, September 2019
6. Appendix: Induction Loop and Vehicle Detector Board Specifications
A. Internal Vehicle Detector Board Specifications
B. Saw - In Loop Specifications
C. Prefab Loop Specifications
Parameter Specification or Requirement
Size 2.5 in. x 3.0 in. (5.1 cm x 7.6 cm)
Power Supply Type Supply from G5 Basestation G5B1 terminals
Voltage 12 DC nominal
Current 50 mA maximum
Connector 3-wire plug-in connector to G5 Basestation G5B1
Parameter Specification or Requirement
3M Detector Loop Sealant 2 each, 1 quart cartridges.
Loop Wire 14 AWG, 19 strands of bare copper, 015 polyvinyl chloride insulation with
.004 nylon jacket, 600v U.L. listed as 90°C MTW, gasoline and oil resistant,
100 feet long.
Parameter Specification or Requirement
Loop Inductance 100 micro henries
Loop Tubing 1/2" schedule 40 PVC
Loop Wire 5 turns of 18 AWG, 7 strands copper with poly vinyl chloride insulation
Lead-in cable 20 feet of 2 conductor (plus shield) 16 AWG. 19 x 29 stranded copper,
Mylar shield with 20 AWG drain wire. Outer jacket to be of high density
polyethylene, suitable for direct burial

Table of Contents