Page 32 of 39 RTE6701-OEM Integration Manual VC27U V1.03 DRAFT.doc
1)
You may need to dismount the PCB from its housing to get at the jumper block J6 or connect the PCB
direct to a programming PCB.
2)
Record the current position of the jumper block J6 so you know what it was set to.
3)
Remove jumpers 4 and 5. If you cannot access the jumpers or if you have firmware which does not
support jumper initiated download then see section 10.4 below.
4)
Connect the PCB to the PC serial port or USB port as appropriate along with a read head (prevent
light entering read head).
5)
Connect the power supply (if required) to the reader and turn on.
6)
Open a DOS box on your computer and enter the following commands for use with the PC’s COM1
serial port:
cd \rt
rx
Alternatively use the
rx2
batch file if using the PC's COM2 port. For other port numbers including
USB serial ports then start the downloader using
rx -d nn
where nn is the COM port number.
For instance in the above example use
rx -d 13
7)
After a few seconds a menu should appear.