SAFETY INFORMATION
10 P/N 595390-01 Rev B 202003
WARNING
To reduce the risks associated with exposure to contaminants, oxygen-deficient atmospheres, and
entanglement, which, if not avoided, could result in serious injury or death:
Ensure the facepiece neck strap is behind your head when the facepiece is donned so that the strap is not
easily snagged but allows enough slack for free movement of the facepiece.
WARNING
To reduce the risks associated with fire and explosion, which, if not avoided, could result in serious injury
or death:
• When cleaning the facepiece, use a dampened cloth to avoid building an electrostatic charge.
• Do not clean or perform maintenance on the facepiece in an explosive environment.
• Do not use an RFID tag reader that has an output power greater than 6 watts while in a flammable
atmosphere.
WARNING
To reduce the risks associated with fire, explosion, exposure to contaminants, and oxygen-deficient
atmospheres, which, if not avoided, could result in serious injury or death:
• Do not alter or repair the facepiece beyond the scope of these instructions.
• Use only 3M-approved parts.
• Follow the regular operational inspection procedures exactly. If there are any operational malfunctions,
remove the respirator from service and tag for repair by authorized personnel.
WARNING
To reduce the risks associated with loss of air supply, exposure to life-threating contaminants, or
oxygen-deficient atmospheres, which, if not avoided, could result in serious injury or death:
• Stay alert when operating this equipment.
• Do not operate this equipment while under the influence of drugs, alcohol, or medication that may affect
vision, dexterity, or judgment.
WARNING
To reduce the risks associated with fire and dermal exposure to contaminants, which, if not avoided,
could result in serious injury or death:
Always wear the appropriate personal protective equipment in accordance with your EHS program. This
respirator only provides protection to the user's respiratory system and to part of the face.