EasyManuals Logo

3M Touch Screen Controller EX 111 User Manual

3M Touch Screen Controller EX 111
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
26 3M™ MicroTouch™ Controller EX USB Reference Guide
3M Touch Systems, Inc. Proprietary Information -- 29489v05
Table 17. Expanded Controller ID Report
Offset Field Size Value Description
0 Report ID 1 0x0C Report ID number
1 Controller type 2 0xXXXX Indicates the type of controller
3 FW major revision 1 0xXX Firmware major revision level
4 FW minor revision 1 0xXX Firmware minor revision level
5 Features 1 0xXX Special features
6 Constants Checksum 2 0xXXXX RAM constants checksum
8 Max Param Write 2 0xFFFF Maximum data for Read
Parameter request
10 Reserved 1 0x41 Reserved
11 Reserved 1 0x41 Reserved
12 Reserved 1 0x41 Reserved
13 Reserved 1 0x41 Reserved
14 Reserved 1 0x41 Reserved
15 Reserved 1 0x42 Reserved
16 Reserved 1 0x41 Reserved
17 Reserved 1 0x41 Reserved
18 Code Checksum 4 0xXXXXXXXX RAM Program Code checksum
22 ASIC type 2 0x01XX ASIC type
Controller Type – The identifier M1 is used. M identifies it as an EX based USB
controller. The 1 identifies it as the first model of this type. This value is treated as an
integer, not two characters. This means that the 1 will be transmitted first.
Note: If you received an identifier of M0, you must issue a Reset with a wValue of 5.
This must be done twice to lock in the values.
FW Major Revision – This can range from 0 to 99. This is a BCD value, i.e., major
revision 23 is sent as 0x23.
FW Minor Revision – This can range from 0 to 99. This is a BCD value, i.e., minor
revision 23 is sent as 0x23.
Features – This identifies the special features of the controller. This is a bitmapped field.
Constants Checksum – 2-byte checksum for the constants data section.
Max Parameter Write -- The largest transfer that can take place. This only affects the
Read Parameter requests.
Code Checksum – 4-byte checksum for the program section of the code.
ASIC Type – this indicates the type and version of the ASIC in the controller. The value
0x0100 indicates the first EX revision. The high byte is used to note major ASIC
changes, such as a new ASIC family, and the low byte indicates changes within a family.

Questions and Answers: