EasyManuals Logo

A.O. Smith 101 Series Service Handbook

A.O. Smith 101 Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
Servicing should only be performed by a Qualified Service Agent
55
OPERATION & SERVICE
UIM - User Interface Module
The UIM’s major components include a Circuit Board with LCD display and a Button Pad
Overlay which contains the five user input buttons.
Service Note: The Ribbon Cable that connects the Button Pad Overlay to the UIM Circuit
Board must be plugged in exactly as shown in the images below; with the metal crimp
connections visible on the plug end and the UIM Circuit Board back facing out. There are six
pins on this Ribbon cable socket, Ensure all six pins are inserted into the Ribbon Cable plug
whenever removing or installing the UIM or Button Pad Overlay.
Failure to connect this Ribbon cable exactly as shown when servicing will render the User
Input Buttons inoperable. This should be checked whenever the nature of the service
complaint is an inoperable or unresponsive controller or UIM.
Button Pad Overlay
J2 Socket - CCB
Communication
UIM Circuit Board Back
J3 Socket - Button Pad
Communication
Ribbon Cable To
Button Pad
Ensure Ribbon Cable Plug
is inserted exactly as shown.
UIM Circuit Board Front
LCD
Screen

Table of Contents

Other manuals for A.O. Smith 101 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the A.O. Smith 101 Series and is the answer not in the manual?

A.O. Smith 101 Series Specifications

General IconGeneral
BrandA.O. Smith
Model101 Series
CategoryWater Heater
LanguageEnglish

Related product manuals