Measurements directly next to appliances:
- Electric stove 500 V/m 10.000 nT
- TV set 5.000 V/m 10.000 nT
- Hi-fi system 500 V/m 5.000 nT
- Hair dryer 1.000 V/m 100.000nT
- Electric blanket 5.000 V/m 5.000 nT
- Dimmer 1.000 V/m 300 nT
- Wall outlet 200 V/m
- Fuse box 300 V/m 500 nT
- Computer screen 200 V/m 1.000 nT
Measurements at larger distance
:
- Beneith a 10kV high-voltage line 500 V/m 5.000nT
- Beneith a 110kV high-voltage line 3.000 V/m 20.000nT
- Beneith a 380kV high-voltage line 10.000 V/m 50.000nT
- In the vicinity of a 380kV substation 15.000 V/m 500.000nT
16.0 Typical readouts in practice
Firmware V 1.0 / © 2005-2013 by Aaronia AG, D-54597 Euscheid, www.aaronia.com