bdi
CW
BDM interface for CodeWarrior™ Debugger, BDI2000 (MPC5xx/8xx) User Manual 22
© Copyright 1992-2001 by ABATRON AG V 1.02
Appendices
A Troubleshooting
Problem
The firmware can not be loaded.
Possible reasons
The BDI is not correct connected with the target system (see chapter 2).
The power supply of the target system is switched off or not in operating range
(4.75 VDC ... 5.25 VDC) --> MODE LED is OFF or RED
The built in fuse is damaged --> MODE LED is OFF
The BDI is not correct connected with the Host (see chapter 2).
• A wrong communication port (Com 1...Com 4) is selected.
Problem
No working with the target system (loading firmware is ok).
Possible reasons
Wrong pin assignment (BDM/JTAG connector) of the target system (see chapter 2).
Target system initialization is not correct --> enter an appropriate target initialization list.
• An incorrect IP address was entered (BDI2000 configuration)
• BDM/JTAG signals from the target system not correct (short-circuit, break, ...).
The target system is damaged.
Problem
Network processes do not function (loading the firmware was successful)
Possible reasons
The BDI2000 is not connected or not correctly connected to the network (LAN cable or media
converter)
• An incorrect IP address was entered (BDI2000 configuration)