Operation Manual / 4 Product description / A200-L
9 Taking a turbocharger out of operation / 9.4 Procedure with two or
more installed turbochargers
© Copyright 2018 ABB. All rights reserved. HZTL4036_EN Revision M August 2018
u Shut off the supply of lubricating oil to the turbocharger.
u Blank off flanges of compressor casing outlet(01), gas inlet(02) and gas outlet(03) by in-
stalling cover plates.
u Observe specifications from enginebuilder.
9.4.2 Continuing to operate the engine
Continue to operate engine in accordance with enginebuilder's instructions. Do not exceed
prescribed power reduction and maximum turbocharger speed.