Maintenance schedule
Recommended maintenance intervals and component replacements are based on
specified operational and environmental conditions. ABB recommends annual drive
inspections to ensure the highest reliability and optimum performance.
Note:
Long term operation near the maximum specified ratings or environmental
conditions may require shorter maintenance intervals for certain components. Consult your
local ABB Service for maintenance recommendations at: www.abb.com/searchchannels
Description of symbols
Recommended annual actions by the user
Recommended maintenance actions by the user
Action Description
I Inspection (visual inspection and maintenance action if needed)
P Performance of on/off-site work (commissioning, tests, measurements or other work)
R Replacement
Action Description
P Quality of supply voltage
I Spare parts
P Capacitor reforming for spare drives and spare capacitors (page 88)
I Tightness of terminals
I Dustiness, corrosion or temperature
P Heat sink cleaning (page 82)
Component Replacement Years from start-up Instruction
3 6 9 12151821
Cooling
Fans, IP21 (UL (NEMA) Type 1) frames R1 to R9
Main cooling fans R1...R5 RR R1…R4: page 83,
R5…R8: page 83,
R9: page 84
Main cooling fans R6...R9 RR
Auxiliary cooling fan for circuit boards RRR5…R9: page 84
Fans, IP55 (UL (NEMA) Type 12) frames R1 to R9
Main cooling fans R1...R5 RRRR1…R4: page 83,
R5…R8: page 83,
R9: page 84
Main cooling fans R6...R9 RR
Auxiliary cooling fan for circuit boards R1...R2 RRRR1…R2: page 85,
R3: page 86,
R4: page 87,
R5…R9: page 84
Auxiliary cooling fan for circuit boards R3...R9 RR
Second auxiliary cooling fan RRR8 and R9: page 87
Aging