EasyManua.ls Logo

ABB ACH580-VCR - Page 85

ABB ACH580-VCR
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACH580 Installation, Operation and Maintenance Manual 85
ACH580-01 Installation
IP55/UL (NEMA) Type 12 Frame Sizes R1…R2
To replace the fan:
WARNING! Obey the Safety instructions on page 2. Ignoring the instructions can
cause physical injury or death, or damage to the equipment.
1. Stop the drive and disconnect it from the power line. Wait for 5 minutes and then
make sure by measuring that there is no voltage. See section Precautions before
electrical work on page 3 before you start the work.
2. Remove the control panel: Press the retaining clip of the IP55 panel cover (2a) and
open the cover (2b). Press the retaining clip of the control panel at the top (2c) and
pull it forward from the top edge (2d).
3. Remove the front cover: Loosen the retaining screws with a screwdriver (3a) and lift
the cover from the bottom outwards (3b) and then up (3c).
4. Unplug the fan power supply wires from the drive.
5. Remove the fingerguard: Insert a screwdriver into the hole of the fingerguard (5a),
bend the front edge of the fingerguard a little away from the drive frame with the
screwdriver (5b) and pull the fingerguard out of the groove (5c).
6. Pull off the fan.
7. Install the new fan assembly in reverse order. Route the wires round the pins.
Note: Make sure that the arrow on the fan points to the same direction as the arrow
on the drive frame.
8. Restore power.
5c
5a
5b
2a
2c
2d
3c
3b
3a
4
7
2b

Table of Contents