ACS 300 User’s Manual 51
Chapter 7 - Drive Parameters
Page 1 parameters
PAGE 1 (*P2)
Press
to change to Page 2.
OUTPUT f
Frequency to motor. This parameter is display only. Jump directly
to local frequency reference setting, parameter LOC FREQ, by
pressing .
REF FREQ/
LOC FREQ
The frequency reference input or local frequency reference.
SPEED
Motor speed in RPM. The indicated value is valid only if
parameter NOM RPM has been set correctly. The motor speed
slip is not compensated. Information is updated four times per
second.
Code Parameter Range Default
Custo-
mer
Page Description
PAGE 4 (*P1) – – – 76 Press
to change to page 1
801 2ACC 1 0.1 - 1800 s 3 52 Parameter set 2 parameters are similar
to the parameters in pages 1 and 2.
802 2DEC 1 0.1 - 1800 s 3 52
803 2NOM RPM (0) 0 - 19999 1500 53
804 2NOM FREQ (0) 50 - 400 Hz 50 53
805 2NOM VOLT (0) 200 - 240 V or
360 - 480 V
220/480V 54
806 2COS PHI (0) 0.40 - 0.90 0.75 54
807 2CON f 1 0.0-200/500Hz 5 54
808 2CON f 2 0.0-200/500Hz 25 54
809 2CON f 3 0.0-200/500Hz 50 54
810 2I LIMIT 0.5 - 1.5 x I
N
1.5*I
N
55
811 2IR-COMP Off/0.1 – 60 V/
Auto
Off 63