ACS 600 MultiDrive Technical Data
A-20 ACS 600 MultiDrive
Input Power
Connection
Voltage (U
1
):
380/400/415 VAC 3-
phase ± 10 % for 400 VAC units
380/400/415/440/460/480/500 VAC 3-
phase ± 10 % for 500 VAC units
525/550/575/600/660/690 VAC 3-
phase ± 10 % for 690 VAC units
525...830 VAC 3-
phase ± 10 % for 830 VAC units
Short Circuit Capability (IEC 439-1): The rated short time withstand
current of ACS 600 MultiDrive is given below.
Frequency: 48 to 63 Hz, maximum rate of change 17 %/s
Input Voltage Unbalance:
± 3 % (EN 60204-1)
Power Factor:
Diode and Thyristor Supply Units
(cos j
1
): 0.97 (fundamental at nominal load)
(cos
j): 0.93...0.95 (total)
IGBT Supply Units
cos j
1
= 1.00 (fundamental at nominal load)
l = I
1
/I
rms
· cos j
1
> 0.98 (total) , where
l is power factor,
I
1
is fundamental input current rms value,
I
rms
is total input current rms value.
Motor Connection
Voltage (U
2
): 0 to U
1
, 3-phase symmetrical.
Frequency: 0 to 300 Hz with 380 to 415 V,
0 to 120 Hz with 525 to 690 V
Frequency Resolution: 0.01 Hz
Continuous Current: 1.0 · I
2N
(normal use)
Short Term Overload Capacity: see rating tables (valid
when output
frequency is > 10 Hz)
Field Weakening Point: 8 to 300 Hz
Switching Frequency: 2 kHz (average)
Frame Type I
cw / 1 s
(kA)
I
pk
(kA)
B1, B2 18 38
B3 37 78
B4, B5 50 105
B4, B5 optional 65 137

Table of Contents

Other manuals for ABB ACS 600 MultiDrive

Related product manuals