Appendix A – ACS/ACC/ACP 601 Technical Data
A-2 ACS/ACC/ACP 601 Frequency Converters
The table continues from previous page.
Pump and Fan
Use (Squared
Load)
ACS 601
Type
I
2Nsq
[A]
P
N
[kW]
Frame
Type
Three-phase supply voltage 380 V,
400 V or 415 V
ACS 601-0020-3 41 18.5 R4
ACS 601-0025-3 47 22
ACS 601-0030-3 62 30 R5
ACS 601-0040-3 76 37
ACS 601-0050-3 89 45
ACS 601-0060-3 112 55 R6
ACS 601-0070-3 124 75 (60)
ACS 601-0100-3 178 90 R7
ACS 601-0120-3 200 110 (100)
Three-phase supply voltage 380 V, 400
V, 415 V, 440 V, 460 V, 480 V or 500 V
ACS 601-0025-5 41 22 R4
ACS 601-0030-5 47 30
ACS 601-0040-5 58 37 R5
ACS 601-0050-5 65 45
ACS 601-0060-5 84 55
ACS 601-0070-5 112 75 R6
ACS 601-0100-5 124 90 (83)
ACS 601-0120-5 164 110 R7
ACS 601-0140-5 193 132
Normal use (10 % overload capacity): Heavy-duty use (50 % or 100 % overload capacity):
I
2N
rated rms output current
I
2hd
rated rms output current
I
2Nmax
rms overload current (allowed for one minute
every 5 minutes):
I
2Nmax
(1/5 min) = 1.1 ·
I
2N
I
2Nmax
(2/15 s) = 1.5 ·
I
2N
(400 and 500 VAC
units)
I
2hdmax
rms overload current (allowed for one minute
every 5 minutes or 2 seconds every 15
seconds). Maximum current depends on
parameter setting, refer to
Firmware Manual
.
I
2hdmax
(1/5 min) = 1.5 ·
I
2hd
I
2hdmax
(2/15 s) = 2.0 ·
I
2hd
(400 and 500 VAC
units) or 1.5 ·
I
2hd
(690 VAC units)
S
N
rated apparent output power
S
hd
rated apparent output power
P
N
typical motor power. The power ratings in kW
apply to most IEC 34 motors. The power
ratings in HP apply to most four pole NEMA
rated motors.
P
hd
typical motor power. The power ratings in kW
apply to most IEC 34 motors. The power
ratings in HP apply to most four pole NEMA
rated motors.
Pump and Fan Use (Squared Load): no overload capacity
I
2Nsq
rated rms output current
The current ratings are the same regardless of the supply voltage
within one voltage range. The rated current of the ACx 60x must
be higher than or equal to the rated motor current to achieve the
rated motor power given in the table
.
Note 1: The maximum allowed motor shaft power is limited to 1.5 ·
P
hd
. If the limit is exceeded, the motor torque and the I
2hdmax
2/15 s current is automatically restricted. The function protects the
input bridge of the ACS 600 against overload.
Note 2: The load capacity (current and power) decreases if the
installation site altitude exceeds 1000 metres, or if the ambient
temperature exceeds 40 °C (or 35 °C with ACS 601-0120-03 and
ACS 601-0140-05 units in Pump and Fan Use). This applies to
units with degree of protection IP 21/22. See Output Current
Temperature Derating on page A-4.
Note 3: The Pump and Fan rating is not to be used with du/dt
filters. du/dt filters are usually needed at the output of 525 V to
690 V units with random wound motors. No du/dt filters are usually
required with form wound motors.
Notes concerning Pump and Fan Use only
Pump and Fan rating is available for ACS 600 with Standard and
Pump and Fan Control Application Programs.
( ) typically achieved motorpower with I
2Nsq
Note 1: The I
2Nsq
currents do not apply to IP 54 units.

Table of Contents

Other manuals for ABB ACS 600

Related product manuals