EasyManua.ls Logo

ABB ACS 600 - NIOC and NIOCP Board Specifications

ABB ACS 600
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A – ACS/ACC/ACP 601 Technical Data
ACS/ACC/ACP 601 Frequency Converters A-15
NIOC and NIOCP
Board Specifications
Data of the external control connection boards of the ACS 600 product
family are given below.
ACS/ACC/ACP 600
NIOC-01 Board
ACP 600
NIOCP-01 Board
Analogue Inputs
The advantage of the
differential analogue
input is that the earth
potential of the device
or transmitter sending
an analogue signal
can differ up to ± 15 V
from the earth
potential of the
ACx 600 chassis
without disturbing the
signal. Differential
input also efficiently
attenuates common
mode disturbances
coupled to control
cables.
ACS 600: Two Programmable Differential
Current Inputs: 0 (4) to 20 mA,
R
in
= 100 Ω
ACC 600: Two Differential Current Inputs:
0 to 20 mA,
R
in
= 100 Ω
ACP 600: One Programmable Differential
Current Input: 0 to 20 mA,
R
in
= 100 Ω
ACS/ACP 600: One Programmable
Differential Voltage Input: ACS 600: 0 (2) to
10 V,
R
in
> 200 kΩ; ACP 600: 0 to 10 V,
R
in
>
200 kΩ
ACC 600: One Differential Voltage Input: 0
to 10 V,
R
in
> 200 kΩ
Common Mode Voltage:
± 15 VDC, max.
Common Mode Rejection Ratio: >
60 dB at
50 Hz
Resolution: 0.1 % (10 bit)
Inaccuracy:
± 0.5 % (Full Scale Range) at
25
°C. Temperature Coefficient:
± 100 ppm/°C, max.
Input Updating Time: 12 ms (ACS 600),
44 ms (ACC 600), 1 ms (ACP 600)
Two Bipolar Differential Voltage Inputs:
± 10 V,
R
in
= 30 kΩ
Common Mode Voltage:
± 20 VDC, max.
Common Mode Rejection Ratio: >
60 dB at
50 Hz
Resolution: 0.02 % (12 bit)
Accuracy: 11 bit
Inaccuracy:
± 0.1 % (Full Scale Range) at
25
°C. Temperature Coefficient:
± 100 ppm/°C, max.
Input Updating Time: 1 ms
Constant Voltage
Output
Voltage: 10 VDC ± 0.5 % (Full Scale Range) at
25 °C. Temperature Coefficient: ± 100 ppm/°C,
max.
Maximum Load: 10 mA
Applicable Potentiometer: 1 kΩ
WR
10 kΩ
Voltage: ± 10 VDC ± 0.5 % (Full Scale Range)
at 25 °C. Temperature Coefficient:
± 100 ppm/°C, max.
Maximum Load: 10 mA
Applicable Potentiometer: >
1 kΩ
Auxiliary Power
Output
Voltage: 24 VDC ± 10 %, Short circuit proof
Maximum Current: 250 mA (130 mA with
NLMD-01 option)
Voltage: 24 VDC ± 10 %, Short circuit proof
Maximum Current: 300 mA
Analogue Outputs
ACS/ACC 600: Two Programmable Current
Outputs: 0 (4) to 20 mA,
R
L
< 700 Ω
ACP 600: One Programmable Current
Output: 0 to 20 mA,
R
L
< 700 Ω
Resolution: 0.1 % (10 bit)
Inaccuracy:
± 1 % (Full Scale Range) at
25
°C. Temperature Coefficient:
± 200 ppm/°C, max.
Output Updating Time: 24 or 100 ms
(ACS 600), 44 ms (ACC 600), 8 ms (ACP 600)
One Bipolar Programmable Voltage Output:
+
10 V,
R
L
> 2kΩ
Resolution: 0.02 % (12 bit)
Accuracy: 10 bit
Inaccuracy:
± 0.1 % (Full Scale Range) at
25
°C. Temperature Coefficient:
± 200 ppm/°C, max.
Output Updating Time: 2ms
Output Rising Time: 3ms

Table of Contents