124 ACS2000 DFE UM 3BHS360367 ZAB E01 REV. K
9.5.2 Toggling between actual signals display and
fault memory
To toggle between actual signals display and fault
history display, press a fast navigation key.
9.5.3 Displaying three actual signals
1. To display the full name of three actual signals,
press and hold the ACT key.
2. To return to the actual signals display, release
the ACT key.
9.5.4 Selecting actual signals
1. To select the actual signals display, press the
ACT key.
2. To select a line where the actual signal is to be
displayed, press the corresponding slow navi-
gation key. A blinking cursor indicates the
selected row.
3. To enter the actual signals selection function,
press the ENTER key.
4. To select a parameter group, press a fast navi-
gation key.
5. To select an actual signal, press a slow naviga-
tion key.
6. To confirm the selection and to return to the
actual signals mode, press the ENTER key.
7. To cancel the selection and keep the original
selection, press any of the mode selection
keys.The selected CDP control panel mode is
entered.
1 L ->
600.0 rpm
1 LAST FAULT
+Overspeed
070730 12:30:02.3256
1 L ->
600.0 rpm
StateINU
MOTOR SPEED
POWER
1 L ->
600.0 rpm
StateINU
MOTOR SP
POWER
ReadyRun
600.00 rpm
75.0 kW
1 L ->
600.0 rpm
StateINU
MOTOR SP
ReadyRun
600.00 rpm
75.0 kW
POWER
1 L ->
600.0 rpm
1 ACTUAL SIGNALS
15 POWER
0.0 kW
1 L ->
600.0 rpm
1 ACTUAL SIGNALS
01 DC VOLTAGE
1000 V
1 L ->
600.0 rpm
2 ACTUAL SIGNALS
05 NP VOLTAGE
1000 V
1 L ->
600.0 rpm
StateINU
MOTOR SP
NP VOLT
ReadyOn
0.00 rpm
0 V
1 L ->
600.0 rpm
StateINU
MOTOR SP
POWER
ReadyOn
0.00 rpm
0.0 kW