18
Mains choke selection
In common DC connections, the ACSM1 drive module(s) connected to AC
supply must be equipped with mains choke(s). Mains chokes are needed
to get the maximum DC power ratings from the ACSM1 drive module(s)
to reduce the AC input current (rms, peak) level
to meet the requirements for harmonic distortion
to balance the supply current in multiple AC input.
Mains choke data
Data for the mains chokes is given below.
Type L Ith Imax
µH A A
CHK-01 6370 4.2 6.2
CHK-02 4610 7.6 11.4
CHK-03 2700 13.1 19.6
CHK-04 1475 22.0 26.3
CHK-05 1130 33.1 52.6
CHK-06 700 47.1 74.0
CHK-07 450 63.0 98.8
CHK-08 355 84.5 140.0
L : Mains choke nominal inductance
I
th
: Maximum allowed continuous current (rms) at 55°C ambient
temperature
I
max
: Maximum allowed short time current (rms). This current is allowed for
maximum 10 s.