EasyManua.ls Logo

ABB AquaMaster 3 Manual

ABB AquaMaster 3
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MODBUS Tables Supplement COI/FET2XX/MOD/TBL–EN
AquaMaster 3
Electromagnetic flowmeter
The smart solution for
potable applications
Introduction
AquaMaster 3
TM
is a range of high performance
electromagnetic flowmeters for the measurement of
electrically-conductive fluids and is normally supplied as
factory-configured, calibrated systems.
This MODBUS tables supplement contains MODBUS
Protocol implementation information and MODBUS
Protocol Register Allocation tables and is applicable to
product firmware version WAJC2103 v01.00.00 or
above.
Detailed specifications and recommendations for using
and implementing MODBUS communications are
contained in the following external publications:
MODBUS Over Serial Line – Specification and
Implementation Guide V1.02. Dec 20, 2006.
http://www.modbus.org/.
MODBUS Application Protocol Specification V1.1b.
Dec 28, 2006. http://www.modbus.org/.
This supplement should be used in conjunction with the
following publications:
Programming Guide (COI/FET2XX–EN)
User Guide (OI/FET2XX–EN)

Other manuals for ABB AquaMaster 3

Question and Answer IconNeed help?

Do you have a question about the ABB AquaMaster 3 and is the answer not in the manual?

ABB AquaMaster 3 Specifications

General IconGeneral
TypeElectromagnetic flowmeter
Measurement PrincipleFaraday's law of electromagnetic induction
Flow Rate RangeDependent on pipe size
Accuracy±0.2% of reading (typical)
Repeatability±0.1% of rate
Power Supply100 to 240 V AC, 50/60 Hz; 24 V AC/DC; Battery
Communication ProtocolsHART, Modbus
Fluid Temperature-40 to +180 °C (-40 to +356 °F) depending on liner
Storage Temperature-40°C to +70°C
Pressure RatingPN10 to PN420 (depends on size and material)
Process connectionFlanged, wafer
Protection RatingNEMA 4X
OutputsAnalog output (4 to 20 mA), Pulse/Frequency output