EasyManua.ls Logo

ABB AWT210 - Pipe Mounting Procedures

ABB AWT210
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 AWT210 PROFIBUS PA 2-WIRE TRANSMITTER | COM/AWT210/PROFIBUS-EN REV. A
…8 PROFIBUS slots
2-electrode conductivity transducer block – slot 2
Index Parameter Access Data Type Size (bytes) Range
STANDARD PARAMETERS
BLOCK_OBJECT R Record  
ST_REV R Simple 
TAG _ DESC RW Simple OctetString 
STRATEGY RW Simple 
ALERT_KEY RW Simple 
TARGET_MODE RW Simple  AUTO
MODE_BLK R Record 
ALARM_SUM R Record 
ANALYZER FIELD DEVICE SPECIFIC TRANSDUCER BLOCK PARAMETERS
COMPONENT_NAME RW Simple OctetString 
PV R Record  
 PV_UNIT RW Simple  
 PV_UNIT_TEXT RW Simple OctetString
 ACTIVE_RANGE RW Simple 
 AUTORANGE_ON RW Simple Bool
 SAMPLING_RATE RW Simple Time_Diff
 NULL_ // reserved by PI
 NUMBER_OF_RANGES R Simple 
  RW Record 

 PV_MIN_SPAN R Simple Float
 SENSOR_RANGE R Record 
 MEASUREMENT_TYPE RW Simple  
  R Record 
  RW Simple  
  R Record 
  RW Simple  
  R Record 
  RW Simple  
 COND_UNITS_MODE RW Simple  
 CELL_CONSTANT RW Simple Float 
 CONC_CURVE_NAME RW Simple OctetString
 CONC_CURVE_TABLE_X_COND RW Array Float  
 CONC_CURVE_TABLE_Y_CONC RW Array Float  
 TEMP_UNIT RW Simple  
 TEMP_COMP_TYPE RW Simple  
 MANUAL_TEMP RW Simple Float 
 AUTO_TC_OPTION RW Simple  
 TC_COEFFICIENT RW Simple Float 
  RW Simple  
 USER_DEF_TC_CURVE_X_TEMP RW Array Float  
 USER_DEF_TC_CURVE_Y_TEMP RW Array Float  
 REFERENCE_TEMP RW Simple Float 
 Reserved by PI
 TEMP_SENSOR_TYPE R Simple  
 TEMP_SENSOR_AR_TRIGGER W Simple  
 TEMP_SENSOR_AR_STATUS R Simple  
 SENSOR_DIAG RW Simple  

Other manuals for ABB AWT210