ABB MEASUREMENT & ANALYTICS | OPERATING INSTRUCTION
AWT420
Universal 4-wire, dual-input transmitter
Measurement made easy
Introduction
The AWT420 is a universal 4-wire, dual-input
transmitter suitable for the measurement and
control of a wide range of parameters including
pH, ORP, conductivity, turbidity/suspended
solids and dissolved oxygen.
The AWT420 supports both traditional analog and
advanced digital EZLink sensors.
This Operating Instruction provides installation,
operation and maintenance procedures for the
AWT420 transmitter. For information on the
sensors, including installation, commissioning,
operation and maintenance procedures, refer to
the specific sensor manual.
For more information
Further publications for the AWT420 transmitter
are available for free download from:
www.abb.com/measurement
or by scanning this code:
Links and reference numbers for the transmitter
publications are also shown below:
Search for/click on:
 

Commissioning Instruction
C 

HART Communications Supplement

HART-EN





PROFIBUS Communications Supplement

PROFIBUS-EN





Ethernet Communications Supplement

ETHERNET-EN
AWT420
Universal 4-wire,
dual-input transmitter

Table of Contents

Other manuals for ABB AWT420

Question and Answer IconNeed help?

Do you have a question about the ABB AWT420 and is the answer not in the manual?

ABB AWT420 Specifications

General IconGeneral
BrandABB
ModelAWT420
CategoryTransmitter
LanguageEnglish

Summary

Health & Safety

Cyber security

Mechanical installation

Electrical installation

Easy Setup

Calibration and sensor setup

Hot plug-in (EZLink sensors only)

Sensor replacement

Provides instructions for replacing existing sensors with new ones.

Operation

Data logging

Password security and access level

Display icons

Configuration (Advanced access level)

Calibrate

Detailed procedures for calibrating various sensor types.

Sensor Setup

Configuration parameters specific to each sensor type.

Device Setup

General transmitter configuration settings like Instrument Tag, Units, and Security.

Input;Output

Configuration options for analog outputs, digital I/O, and relay outputs.

Process Alarm

Setup and configuration for process alarms.

Media Card

Settings related to data logging, saving configurations, and formatting the SD card.

Control

Configuration of PID control loops and associated parameters.

Communication

Settings for optional communication modules (Modbus, Profibus, HART, Ethernet, Bluetooth).

Sensor setup

2-electrode conductivity

Settings for configuring 2-electrode conductivity sensors.

4-electrode conductivity

Settings for configuring 4-electrode conductivity sensors.

pH;Redox;ORP

Settings for configuring pH, Redox, and ORP sensors.

RDO

Settings for configuring RDO (Dissolved Oxygen) sensors.

Turbidity;Suspended solids

Settings for configuring Turbidity and Suspended Solids sensors.

Calibration procedures

2-electrode conductivity

Procedures for calibrating 2-electrode conductivity sensors.

2-electrode conductivity, resistivity or concentration calibration

Steps for calibrating conductivity, resistivity, or concentration measurements.

4-electrode conductivity

Procedures for calibrating 4-electrode conductivity sensors.

4-electrode conductivity calibration

Steps for calibrating 4-electrode conductivity measurements.

pH;Redox;ORP

Procedures for calibrating pH, Redox, and ORP sensors.

1-Point automatic calibration

Steps for an automatic 1-point calibration for pH/Redox/ORP sensors.

2-Point automatic calibration

Steps for an automatic 2-point calibration for pH/Redox/ORP sensors.

In Process calibration (pH)

Procedure for calibrating pH sensors using the actual process sample.

Turbidity Total Suspended Solids (TSS)

Procedures for calibrating Turbidity and Total Suspended Solids sensors.

Turbidity TSS calibration

Procedures for calibrating Turbidity and TSS sensors.

TSS calibration

Procedures for calibrating TSS sensors.

RDO

Procedures for calibrating RDO (Dissolved Oxygen) sensors.

1-Point calibration

Instructions for performing a 1-point calibration for RDO sensors.

2-Point calibration

Instructions for performing a 2-point calibration for RDO sensors.

Troubleshooting

Diagnostic messages

Guides users on diagnosing and resolving common issues with the AWT420 transmitter.

Specification

Approvals, certification and safety

Lists safety approvals, certifications, and regulatory compliance information.

Appendix D PID control

Related product manuals