Type | Temperature transmitter |
---|---|
Display | Optional LCD display |
Input | RTD, Thermocouple, Resistance |
Output | 4-20 mA, HART |
Accuracy | ±0.1% of span |
Ambient temperature | -40°C to +85°C (-40°F to +185°F) |
Housing material | Aluminum, Stainless steel |
Communication | HART |
Configuration | Via HART protocol, configuration tools |
Power supply | 10.5 ... 45 V DC (depending on version and load) |
Measurement Range | Depends on sensor type (RTD, Thermocouple, etc.) |
Protection Rating | IP66 |
Sensor Type | RTD, Thermocouple |
General instructions and warnings for safe operation and product handling.
Explains the structure of warnings (DANGER, WARNING, CAUTION, NOTICE).
Describes the specific applications and purposes for which the device is designed.
Lists actions considered improper use of the device.
Details the specific ATEX and IECEx markings for transmitters and LCD indicators.
Lists ATEX/IECEx intrinsic safety and non-sparking certifications for the transmitter.
Explains how to verify intrinsic safety compliance with standards.
Details hookups and requirements for ATEX Zone 0 and Zone 1 installations.
Procedures for commissioning in potentially explosive atmospheres.
Lists FM and CSA markings for transmitters and LCD indicators.
Details FM Intrinsically Safe and CSA Non-Incendive certifications for transmitters.
Explains how to verify intrinsic safety compliance with standards.
Procedures for commissioning in FM/CSA environments.
Describes sensor redundancy and input capabilities.
Explains the use of two sensor inputs for enhanced system availability.
Further details on sensor redundancy and drift monitoring.
Detailed steps for mounting the transmitter on the measuring inset.
Crucial safety guidelines for electrical connections, especially in hazardous areas.
Measures to protect the transmitter from electrical interference and overvoltage.
Diagrams and descriptions of terminal assignments for RTD/resistors.
Diagrams and descriptions of terminal assignments for thermocouples and RTDs.
Information on the TTH300's certification for custody transfer measurements.
Essential checks before initiating device commissioning.
Safety precautions before operating the device.
Steps to enable and disable write protection for device configuration.
Information on monitoring operating data and diagnostic values.
How to access detailed error descriptions for PROFIBUS/Fieldbus.
Table of HART error messages, causes, and remedies.
Table of PROFIBUS/Fieldbus error messages, causes, and remedies.
Safety precautions related to hot media and sufficient cooling.
Dangers and restrictions associated with device repair.