195
1SVC 440 795 M0100
5CL settings
All CL settings can only be carried out on models provided
with keypad and LCD display.
CL-SOFT can be used to set all models via the software.
Password protection The logic relay can be protected by a password against
unauthorised access.
In this case the password consists of a value between
000001 and 999999. The number combination 000000 is
used to delete a password.
Password protection inhibits access to selected areas. The
system menu is always protected when a password is
activated.
The password can protect the following entries and areas:
Start or modification of the program
Transfer of a circuit diagram to the memory module
Change of the RUN or STOP mode.
Calling and modification of function block parameters
All settings of the real-time clock.
Modifications of all system parameters.
Communication with the individual device
Disabling of the password delete function.
h
Factory setting:
0000, no password present and none active, circuit
diagram area selected.