II F 3-3
3ADW000072R0501_DCS600_System_description_e_e
Fig. 3.3/1: Control and status
Voltage
switched off
Switch on
inhibit
not ready
to swich on
Power ON
OFF 1 (MCW Bit0=0)
Status Disable
(MSW Bit6=1)
Status Not ready for startup
(MSW Bit0=0)
ready to
switch on
Status Ready for startup
(MSW Bit0=1)
Main Control word basic condition
(MCW=XXXX XXXX XXXX X
110
)
ON (MCW Bit0=1)
Inhibit
Operation
active
operation
disabled
disable operation
(MCW Bit3=0 RUN)
Ready
Status Ready for operation
Release
operation
(MCW Bit3=1)
A
BC
D
OFF1
(n=0 / I=0) OR (MCW Bit3=0 (RUN))
OFF1
(MCW Bit0=0)
from every device status
OFF3
active
Stop drive *)
according to
parameter 21.04
eme stop mode
(MSW Bit5=0)
n=0 / I=0
Emergency Stop
OFF3
(MCW Bit2=0)
from every device status
OFF2
(MSW Bit4=0)
Emergency Off
OFF2
(MCW Bit1=0)
from every device status
Fault
Stop drive
(MSW Bit3=1)
Fault
from every device status
Enable
Operation
Release electronics and pulses
(MSW Bit2=1)
RFG-output free
(MCW Bit4=1)
RFG: Enable
output
RFG-output released
(MCW Bit5=1)
B
RFG: Accelerator
enable
Setpoint released
(MCW Bit6=1)
C
D
A
Operating
state
D
n = n_set
(MSW Bit8=1)
MCW = Main Control Word
MSW = Main Status Word
n = Speed
I = Power input current
RFG = Ramp Function Generator
Error corrected
confirm by
RESET (MCW Bit7= 1)
BCD
CD
RFG-output
disable
(MCW Bit4=0
RAMP_OUT_ZERO)
RFG stop
(MCW Bit5=0
RAMP_HOLD
)
Setpoint
disabled
(MCW Bit6=0
RAMP_IN_ZERO)
ABB Drive Profile
for DC-drives
Control and
Status
Inching 1 Active
Drive Running
Inching 1 setpoint
to speed control
MCW: Bit 4 = 0 and Bit 5 = 0 and Bit 6 = 0
INCHING 1
ON (MCW Bit 8 = 1)
Purpose: Main speed ref. is deactivated
Inching 2 setpoint
to speed control
INCHING 2 ON (MCW Bit 9 = 1)
Inching 2 Active
Drive Running
INCHING 1 OFF (MCW Bit 8 = 0)
INCHING 2
OFF (MCW Bit 9 = 0)
ON INHIBIT
OFF
RDY_ON
RDY_RUN
(MSW Bit1=1)
RDY_REF
Status Operation released
OFF_3_STA
Coast Stop
(no torque)
OFF_2_STA
TRIPPED
Status:
Status:
Status:
RUN
RAMP_OUT_ZERO
RAMP_HOLD
RAMP_IN_ZERO
AT_SETPOINT
active
active
E
F
E
F
dcs_600\docu\fig_4.dsf
Stop drive *) according to
- DECELER TIME (22.02)
at speed control
- TORQ RAMP DOWN (25.06) /
TORQ REF A FTC (25.02)
at torque control
then open Main Contactor
Status:
OFF
(not ready for startup,
MSW Bit0=0)
*) while the drive is being stopped,
status bit RDY_REF (MSW bit 2)
remains at "1" as long as the drive
generates torque.
Inhibit
converter pulses
Status:
Operation Disabled
(MSW Bit2=0 RDY_REF)

Other manuals for ABB DCS 600 MultiDrive

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS 600 MultiDrive and is the answer not in the manual?

ABB DCS 600 MultiDrive Specifications

General IconGeneral
BrandABB
ModelDCS 600 MultiDrive
CategoryMedia Converter
LanguageEnglish

Related product manuals