II F 1-2
3ADW000072R0501_DCS600_System_description_e_e
Design and commissioning tools
DriveWindow
PC program for commissioning and maintenance un-
der Windows
®
for:
Parameter setting
Fault detection
Trending
Data logger
Fault logger
Local operation (Drives Panel)
CDP 312 removable control and display panel with
plain text display for:
Drive control signal
Parameter setting
Fault detection
Parameter uploading and downloading
Local operation
Monitoring functions
Self-test
Fault logger
Motor protection
In the event of:
• Speed feedback error
• Overtemperature
• Overload
• Overspeed
• Zero speed
• Armature overcurrent
• Armature ripple
• Armature overvoltage
• Minimum field current
• Field overcurrent
• Motor stalled
Power converter protection
• Overtemperature
• Software errors (watchdog function)
Incorrect supply protection
• Mains overvoltage and undervoltage
• Auxiliary undervoltage
• Incorrect mains phase sequence (only inform.)
Basic functions
All units are provided with the same digital control
boards and software. The DCS 600 MultiDrive flexi-
bility allows the user to configure functions of the drive
easily, suitable for different applications. Functions of
the DCS 600 MultiDrive are normally activated by
parameters.
The basic software includes the following options:
• Processing the speed reference with a speed ramp
generator (S-ramp capability, accel/decel ramp)
• Processing the speed feedback
• Speed controller
• Torque reference processing
• Current controller
• Field weakening
• Automatic/manual field reversal
• Autotuning of current controller
• Speed monitor
• Drive control logic
• Remote/local operation
• Emergency stop
• Electronic circuits are not sensitive to line phase
sequence
• Electrical and mechanical brake control
• Motor overload supervision
• Dual field
• Programmable analogue outputs
• Field supply
• Master follower via fibre optics
• 12-pulse link
Controlling and operating
via I/O's
analogue and digital inputs and outputs
via bus systems
e.g.: Profibus, Modbus Plus, AF100 etc.
via HMI (Human Machine Interface)
Outputs:
Alarms
Faults
Status information
Parameter setting
Local control of the drive