[544] Absolute Accuracy
6 Product Specification RobotWare Options for BaseWare OS 4.0
Performance
Once the Absolute Accuracy parameter file is loaded and activated, the robot can be
used.
Absolute Accuracy is active in:
- Motion function based on robtarget (MoveJ, MoveL, MoveC and ModPos)
- Reorientation jogging
- Linear jogging (no online compensation as the user defines the physical
location, but absolute coordinates are determined for the active pose and shown
in jogging window)
- Tool definition (4, 5, 6 point tool definition, room fixed TCP, stationary tool)
- Workobject definition
Absolute Accuracy is inactive in:
- Motion function based on a jointtarget (MoveAbsJ). Independent joint
- Joint based jogging
- External axes
- Track motion
- Any feature not listed in Absolute Accuracy is active in
For joint based motions, switching to the jogging window and selecting a cartesian jog
mode (Linear, Reorient) will show the correct absolute coordinates. Similarly creation
of a robtarget at a point taught by joint based motion will be absolutely accurate.
Requirements
Each Absolute Accuracy robot is shipped with an error parameter file that is unique to
that robot. This file must be loaded into the controller and subsequently activated in
order to use Absolute Accuracy. Absolute Accuracy functionality may also be
deactivated. Both actions require a cabinet restart.
Supported robot types
Please contact your local ABB office in order to get the latest list of supported robot
types.
RAPID instructions included in this option
No specific RAPID instructions are included.