[542] ScreenViewer
Product Specification RobotWare Options for BaseWare OS 4.0 9
[542] ScreenViewer
This option adds a user window to display user defined screens with advanced display
functions. The user window can be displayed at any time, regardless of the execution
state of the RAPID programs.
User defined screens
The user defined screens are composed of:
• A fixed background with a size of 12 lines of 40 characters each. These characters
can be ASCII and/or horizontal or vertical strokes (for underlining, separating or
framing).
• 1 to 5 function keys.
• 1 to 4 pop-up menus containing from 1 to 10 choices.
• 1 to 30 display and input fields defined by:
- Their position and size.
- Their type (display, input).
- Their display format (integer, decimal, binary, hexadecimal, text).
- A possible boundary with minimum and maximum limits.
Example of a user defined screen. The ### represent the fields.
Advanced Display functions
The user defined screens run independently of the RAPID programs.
Some events occur on a screen (new screen displayed, menu choice selected, function
key pressed, field modified, ...). A list of user screen commands can be associated with
any of these events, then when the event occurs, the command list will be executed.
| XT
| ##
| ##
| ##
| ##
| ##
| ##
| ##
| ##
Program number: ###
SpotTim File
View
Next
Prev.
(Copy)
Valid
PHASES
SQUEEZE
PREHEAT
COOLING
## HEAT
COLD
LASTCOLD
POSTHEAT
HOLD
Heat stepper: ###
interpolated: ##
| START
|
| ####
|
| ####
|
|
| ####
|
| END
|
|
| ####
|
|
|
| ####
|
| Tolerance: ###%
| Force: ###daN
| Forge: ###daN
|
| Fire chck: ###
|
| Err allow: ###%
| Numb err: ###
| CURENT (A)
|