1 Safety, service
1.2.6 Risks associated with live electric parts
3HAC 16245-1 A 13
Units inside the controller, e.g. I/O modules, can be supplied with power from an exter-
nal source.
The mains supply/mains switch
The power unit
The power supply unit for the computer system (230 VAC)
The rectifier unit (400-480 VAC and 700 VDC. Note: Capacitors!)
The drive unit (700 VDC)
The service outlets (115/230 VAC)
The power supply unit for tools, or special power supply units for the machining pro-
cess
The external voltage connected to the control cabinet remains live even when the
robot is disconnected from the mains.
Additional connections
Voltage related
risks, manipula-
tor
A danger of high voltage is associated with the manipulator in:
The power supply for the motors (up to 800 VDC)
The user connections for tools or other parts of the installation (max. 230 VAC, see
Installation and Commissioning Manual)
Voltage related
risks, tools, mate-
rial handling
devices, etc
Tools, material handling devices, etc., may be live even if the robot system is in the OFF
position. Power supply cables which are in motion during the working process may be dam-
aged.