Refitting motor axis 1
This procedure describes how to refit motor axis 1.
NoteAction
xx1000001096
Make sure the o-ring on the circumference of
the motor is seated properly. Lightly lubricate
the o-ring with grease.
1
Parts:
Circumference of motor
O-ring
Note
The o-ring must be replaced when re-
placing the motor.
CAUTION
The motor weighs 29 kg! All lifting equipment
used must be sized accordingly!
2
Connect to connector R2.MP1
+ : pin 2
-: pin 5
In order to release the brake, connect the 24
VDC power supply.
3
xx1400000986
Foundry Plus:
Apply Loctite 574 flange sealant on the contact
surface.
4
Continues on next page
278 Product manual - IRB 6660
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.
4 Repair
4.6.1 Replacing motor, axis 1
Continued

Table of Contents