EasyManua.ls Logo

ABB IRB 760-450/3.2 - Page 166

ABB IRB 760-450/3.2
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
A
xx0600002694
Remove the cable gland cover at the cable
exit by unscrewing its attachment screw on
the inside.
Note
Make sure the gasket is not damaged!
A: Screw securing the cable gland
Disconnect connectors at axis 6 motor.5
xx1000001336
Remove the metal clamp that holds the
cable at the tilt house, by removing its nuts.
6
Carefully pull the cable harness out of motor
axis 6.
7
Continues on next page
166 Product manual - IRB 760
3HAC039838-001 Revision: M
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness, upper end (incl. axis 6)
Continued

Table of Contents

Related product manuals