Order Number 10D1475 _ N____2 ___ _ _ ___ _ _ _
Enclosure Classification
IEC 529, IP65, NEMA 4X
Continuous Submergence: IEC 529, IP68, NEMA 4X, 33 ft H
2
0
(10 m H
2
O) Continuous Duty. Signal cable permanently installed
(Remote only).
Accidental Submersion, IEC 529, IP67, 30 ft H
2
0/48 h (9 m H
2
O/48 h)
(NEMA 4X)
1
4
5
Fluid Temperature Range
Integral Converter to 65
o
C (149
o
F)
Remote Converter to 121
o
C (250
o
F)
[Refer to operating conditions curve in Specifications section for allowable
combinations of fluid & ambient temperatures]
1
2
Output Current
No Output Signal Required
0-20 mA DC
4-20 mA DC
A
B
C
Output Options
No Scaled Output Required
Active Scaled Pulse Forward & Zero Return
Active Scaled Pulse Forward & Reverse
Data Link RS232C
Data Link RS485
1
2
4
5
6
Communication Mode
Not applicable
ASCII
HART Protocol
1
2
4
Coil Drive Frequency
7-1/2 Hz (60 Hz line frequency)
15 Hz (60 Hz line frequency)
15 Hz (DC power, in vicinity of 60 Hz line)
6-1/4 Hz (50 Hz line frequency)
12-1/2 Hz (50 Hz line frequency)
6-1/4 Hz (DC power, in vicinity of 50 Hz line)
12-1/2 Hz (DC power in vicinity of 50 Hz line)
7-1/2 Hz (DC power, in vicinity of 60 Hz line)
1
2
3
4
5
6
7
8
Additional Options
Empty Pipe Detector
None
HART Protocol & Empty Pipe Detector
HART Protocol
1
2
3
4
Mounting Hardware Kit
Standard Kit: Steel Bolts & Nuts, Centering Device, Klinger Sil C-4401 Gaskets
Optional Kit: Steel Bolts & Nuts, Centering Device, Teflon Gaskets
Standard Kit Not Required
C
E
X
Converter
Required
Not Required (Primary only)
1
2
10D1475 MINI-MAG MAGNETIC FLOWMETER INSTRUCTION MANUAL