Vacuum full vacuum at 212
o
 F (100
o
 C) for 
1/10 - 3 in. (3 - 80 mm) sizes
full vacuum at 176
o
 F (80
o
 C) for 4 in. (100 mm)
size
Meter Capacity specified on Flowmeter data tag (equal to max
flow capacity in engineering units). This factor is
equivalent to a flow velocity of 32.81 ft/s in the
metering tube.
Physical Characteristics
Outline Dimensions
Magnetic Flowmeter with 
integral Signal Converter
Refer to Figure 2-1
Remote w/ General Purpose or
FM Class I, Div.2 Box
Refer to Figure 2-2
Remote w/ Explosion-Proof Box Refer to Figure 2-3
Remotely Mounted
Signal Converter
Refer to signal converter instruction manual
Conduit Connections two 1/2 inch NPT internally threaded entrances
in Flowmeter junction box
Cable Length, Remote Converter NEMA 4X & Accidental Submersion - 250 ft.
Continuous Submergence - 100 ft.
Meter Weight
TABLE 1-2. METER WEIGHTS
METER SIZE INTEGRAL REMOTE EXPLOSION PROOF
REMOTE
in. mm lbs. kg lbs. kg lbs. kg
1/10
5/32
1/4
3/8
1/2
1
1 1/2
2
3
4
3
4
6
10
15
25
40
50
80
100
9
9
9
9
9
10
11
12
16
22
4.1
4.1
4.1
4.1
4.1
4.5
5
5.4
7.3
10
4
4
4
4
4
4
5
7
10
16
1.8
1.8
1.8
1.8
1.8
1.8
2.3
3.2
4.5
7.3
5
5
5
5
5
5
6
8
11
17
2.3
2.3
2.3
2.3
2.3
2.3
2.7
3.6
5
7.7
Remotely Mounted
Signal Converter
Refer to signal converter instruction manual
NOTE
Any maximum (range) between 0.02 x Meter Capacity & 1.0 x Me-
ter Capacity is available with HART or standard software. 
10D1475 MINI-MAG MAGNETIC FLOWMETER INSTRUCTION MANUAL
1-8 INTRODUCTION