Vibration Limit
Integrally Mounted *5 to 14 Hz, 0.10 inch,
14 to 2000 Hz, 1 g
* 
Signal converter must be remotely mounted if 
   these limits are exceeded.
Remotely Mounted 5 to 14 Hz, 0.20 inch
14 to 2000 Hz, 1.5 g
Materials of Construction
Meter Liner TEFZEL (ETFE)
Electrode Assemblies Hastelloy-C, Tantalum, Zirconium or Platinum
materials as specified (ref: Application Guide
PMI IV.C.10)
Meter Housing carbon steel, all welded construction, epoxy finish
Electronics Housing die cast aluminum, epoxy finish, 316 sst attach-
ment screws, 1/2 in. NPT conduit connections;
gasketed covers
Installation Kit includes 2 gaskets, mounting studs and nuts,
flange adaptor device when required.
Safety Classification Refer to Section 1.2
10D1475 MINI-MAG MAGNETIC FLOWMETER INSTRUCTION MANUAL
INTRODUCTION 1-9