Enclosure Classification with
or without Signal Converter
NEMA 4X, IEC 529 IP65
Accidental Submergence IEC 529 IP67, 33 feet H
2
O/48 h (10 m H
2
O /48 h)
Continuous Submergence IEC 529 IP68, 33 feet H
2
O (10 m H
2
O)
Ambient Temperature Limits
MODEL LIMITS
10D1475
w/ Integral Converter
-4 to 131
o
F
(-20 to 55
o
C)
10D1475
w/ Remote Converter
-40 to 150
o
F)
(-40 to 65
o
C)
Process Limits
Temperature Limits
NOTE
Signal converter must be remote mounted if liquid temperature ex-
ceeds value listed for a given ambient temperature. Liquid tem-
perature must not exceed 250
o
F (121
o
C) in any event.
Pressure
Temperature Pressure
oF
o
CpsiMPa
100 40 740 5.11
150 65 720 4.96
250 120 650 4.50