Protect electronic components from electrostatic discharge damage by earthing tools and personnel.
Specifies Torx T15 for cover removal and Torx T20 for PCB removal.
Details required LV board (1SFB636068D1011) and HV board (1SFB636068D1013) versions for Torque Control.
Mark cables, disconnect main voltage, other cables, discharge tools/personnel, and remove front cover.
Disconnect and remove old HV board, then remove old LV board.
Mount new LV and HV boards, reconnect all cables, and perform current transformer checks.
Switch on power, access Service Settings, confirm PCB change, and select display language.
Configure essential parameters like CT Ratio, Bypass settings, and SOP values.
Complete programming, set motor current/protections, and consult Torque Control manual.