EasyManua.ls Logo

ABB PST User Manual

ABB PST
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation
and maintenance manual
Softstarters
Type PST/PSTB
Low Voltage Products & Systems
Power on
Protection
Fault
Power on
Protection
Fault
P
o
w
e
r o
n
P
rote
ction
Fault
Power on
Protection
Fault
P
ow
er o
n
Protection
Fault
AC1006.9
1SFC132001M0202

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB PST and is the answer not in the manual?

ABB PST Specifications

General IconGeneral
BrandABB
ModelPST
CategoryController
LanguageEnglish

Summary

Safety Information

Chapter 2: Quickstart

Connection

Provides step-by-step instructions for connecting the softstarter.

Configuration

Guides the user through the initial configuration settings for the softstarter.

Start of the motor

Explains how to start the motor using the softstarter.

Chapter 4: Mounting

Mounting

General guidance on mounting the softstarter unit.

Chapter 5: Connection

Electrical connection

Describes the main electrical connection procedures for the softstarter.

Main circuit

Details how to connect the main power circuit in line or delta configurations.

Control voltage and control circuit

Explains connections for control voltage and the control circuit.

Start and Stop, terminals 4, 5, 8, 9, 10, 11

Details the wiring for start/stop commands using internal or external control.

Chapter 6: Human Machine Interface (HMI)

Chapter 7: Settings and configuration

Settings

Outlines the two primary methods for performing settings and configuration.

Application Setting

Guides through setting predefined parameters for specific applications.

Basic Settings

Covers essential start/stop parameters for quick setup.

Functional Settings

Details parameters organized by function, for advanced setup.

Protections

Covers configuration of various protection functions like overload and locked rotor.

Chapter 8: Fieldbus communication (option)

Chapter 10: Functions

Setting Current

Explains how to set the rated motor current for the softstarter.

Start Ramp

Details how to configure the motor start ramp time.

Stop Ramp

Explains how to set the motor stop ramp time for controlled stopping.

Initial voltage

Sets the starting voltage level for the motor start ramp.

End voltage

Sets the final voltage level where the stop ramp ends.

Current limit

Sets the maximum current limit during motor start.

Motor overload protection

Configures the integrated motor overload protection function.

Locked rotor protection

Enables and configures the locked rotor protection feature.

Underload protection

Configures the underload protection to prevent motor damage.

Phase imbalance protection

Sets up protection against phase current imbalances.

High current protection

Configures protection against excessive motor current.

Phase reversal protection

Enables protection against incorrect phase sequence.

PTC protection

Details the configuration for PTC thermistor motor protection.

Chapter 11: Trouble shooting

General problems and faults

Lists common problems, their possible causes, and solutions.