Softstarters Type PSE18...PSE370
Installation and commissioning manual
PSE 18-600-70
PSE 18-600-70
PSE 18-600-70

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB PSE 72 and is the answer not in the manual?

ABB PSE 72 Specifications

General IconGeneral
Rated Operational Current - Ie72 A
Degree of ProtectionIP20
Output currentUp to 72A
Rated Operational Voltage220-690V AC
Rated Operational Power - Motor (440V)45kW
Rated Operational Power - Motor (500V)45 kW
Rated Operational Power - Motor (690V)75kW
Initial Voltage During Start30-70%
Ramp Time1-30 seconds
Output Voltage at StartAdjustable
Input voltage range220-690V AC
Output voltage220-690V AC
Operating temperature range-25°C to +60°C

Summary

Chapter 1 Introduction

1.2 Installation and Commissioning Manual

Outlines the scope and purpose of the installation and commissioning manual.

Chapter 2 Quickstart

Quickstart

Provides a concise guide for connecting, configuring, and starting the softstarter.

Chapter 4 Mounting

Mounting

Guidelines and requirements for physically installing the softstarter.

Chapter 5 Connection

Electrical connection

Details the electrical connection procedures for the softstarter.

Connection of the operational power circuit

Specifics on connecting the main power lines to the softstarter.

Control supply and control circuit

Instructions for connecting control supply voltage and control circuits.

Chapter 6 Human-Machine Interface (HMI)

Chapter 7 Functions and configuration

List of available parameters

Comprehensive list of configurable parameters with their settings.

Basic settings principal

Guides through the basic configuration of frequently used parameters.

Rated Current Ie of motor

How to set the rated motor current parameter for the softstarter.

Start Ramp Time

Configuration of the time taken for the softstarter to reach full voltage.

Stop Ramp Time

Configuration of the time taken for the softstarter to ramp down.

Current Limit

Function to limit the starting current by adjusting output voltage.

Electronic Motor Overload Protection E.O.L.

Configuration of motor overload protection classes and reset types.

Chapter 9 Maintenance

Chapter 10 Troubleshooting

Tripping events

Lists and explains various event codes and their causes.

Start up problems and faults

Common issues encountered during startup and their solutions.

Fault indications

Details specific fault codes, their causes, and solutions.

Protection indications

Explains indications related to motor overload, underload, and locked rotor protection.

Chapter 11 Wiring diagrams

Circuit diagram PSE18...PSE370 (Fuse and contactor version)

Electrical schematic for the fuse and contactor version.

Circuit diagram PSE18...PSE370 (MCCB version)

Electrical schematic for the MCCB version.