ABB Relion RER615 - User Manual

ABB Relion RER615
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
RELION® PRODUCT FAMILY
Grid Automation
REC615 and RER615
Operation Manual

Table of Contents

Other manuals for ABB Relion RER615

Questions and Answers

  • M
    Michael ClarkAug 8, 2025
    What to do if CMT data points are updating from Application Configuration in ABB Control Unit?
    • C
      christinasmithAug 8, 2025
      If CMT data points are updating from Application Configuration in your ABB Control Unit, it may be because when some AFLs are added to the ACT logic, the related data points are again synchronized to the Communication Management tool although the data are already in the selected list. Verify the DNP3 mapping if a new AFL has been added to the ACT logic as some signals may have disappeared.
  • R
    Randy McclureAug 21, 2025
    How to fix slow or no update of data in ABB Control Unit?
    • M
      Monica JohnsonAug 21, 2025
      If you experience slow or no data updates and disabled reports with your ABB Control Unit, manually select the check boxes for clients of all visible 61850 data sets in the IEC 61850 Configuration tool. Refer to the engineering guide for detailed instructions. This enables reporting for the data sets, and report control blocks should appear on the Report Control tab.

Summary

Section 3 REC615 and RER615 overview

PCM600 tool

Introduces the PCM600 tool for managing the protection relay lifecycle.

Section 4 Using the HMI

Using the local HMI

Guides on using the Local HMI, including login, logout, and basic operations.

Using the Web HMI

Guides on accessing and using the Web HMI for relay management.

Section 5 Protection relay operation

Relay parametrization

How to set protection relay parameters using LHMI, WHMI, or PCM600.

Section 6 Operating procedures

Section 7 Troubleshooting

Fault tracing

Procedures for identifying hardware, runtime, and communication errors.

Section 8 Commissioning

Commissioning checklist

A checklist of tasks and preparations before starting commissioning work.

Testing protection relay operation

Procedures for testing relay functions and operations.

ABB Relion RER615 Specifications

General IconGeneral
Voltage LevelMedium Voltage
Current Rating1 A / 5 A
Frequency50/60 Hz
Communication ProtocolsIEC 61850, Modbus, DNP3
DisplayLCD
Binary InputsUp to 16
Binary OutputsUp to 8
Protection FunctionsOvercurrent, earth fault
Mountingrack mounting
InputsAnalog Inputs
OutputsBinary Outputs
Operating Temperature-25 to +55 °C
EnclosureIP20